800G transceivers for 500 m links

The workhorse AI-cluster link: DR8 on one MPO-16 or 2xDR4 on two MPO-12 connectors over parallel single-mode fiber. Compare power and connectors by maker.

31 sourced modulesChecked 2026-11-11Rating conditions

Accelink DR8 OSFP LPOAccelinkOSFPDR85001Dual MPO-127.51LPODemonstrated2026-11-11
Accelink RTXM600-201AccelinkOSFPDR85001———Catalogued2026-11-11
Accelink RTXM600-400AccelinkQSFP-DDDR85001———Catalogued2026-11-11
Arista LPO-800G-2DR4AristaOSFP2xDR45001Dual MPO-12 APC92LPOCatalogued2026-11-11
Arista LPO-800G-DR8AristaOSFPDR85001MPO-16 APC92LPOCatalogued2026-11-11
Cisco OSFP-800G-DR8CiscoOSFPDR85001Dual MPO-12 APC171—Catalogued2026-11-11
Cisco OSFP-800G-DR8PCiscoOSFPDR85001MPO-16 APC171—Catalogued2026-11-11
Coherent FTCE4516E1PXMCoherentQSFP-DDDR85001MPO-16——Catalogued2026-11-11
Eoptolink DR8 OSFP LPOEoptolinkOSFPDR85001—81LPODemonstrated2026-11-11
Eoptolink DR8 QSFP-DD LPOEoptolinkQSFP-DDDR85001—81LPODemonstrated2026-11-11
Eoptolink EOLO-138HG-5H-XDXEoptolinkOSFP8x100G DR5001Dual MPO-12——Catalogued2026-11-11
Eoptolink EOLO-138HG-5H-xDxLxEoptolinkOSFP2xDR45001Dual MPO-12—LPOCatalogued2026-11-11
Eoptolink EOLO-138HG-5H-XMXEoptolinkOSFP8x100G DR5001MPO-16——Catalogued2026-11-11
FS LPO-800G-2DR4FSOSFP2xDR45001Dual MPO-12 APC8.51LPOCatalogued2026-11-11
FS OSFP-2FR4L-800GFSOSFP2xFR4L5001Dual duplex LC UPC151DSPCatalogued2026-11-11
FS OSFP-DR8-800GFSOSFP2xDR45001Dual MPO-12 APC16.51DSPCatalogued2026-11-11
FS OSFP800-DR8-B1FSOSFPDR85001MPO-16 APC16.51DSPCatalogued2026-11-11
FS QDD-DR8-800GFSQSFP-DDDR85001MPO-16 APC16.51DSPCatalogued2026-11-11
FS QDD-DR8-800G (dual MPO-12)FSQSFP-DD2xDR45001Dual MPO-12 APC16.51DSPCatalogued2026-11-11
InnoLight 2xDR4 OSFP InnoLightOSFP2xDR45001Dual MPO-12 APC——Catalogued2026-11-11
InnoLight DR8 OSFP InnoLightOSFPDR85001MPO-16 APC——Catalogued2026-11-11
Juniper OSFP-2X400G-DR4-PJuniperOSFP2xDR45001Dual MPO-12 APC161—Catalogued2026-11-11
Lumentum 2xDR4 OSFP DSPLumentumOSFP2xDR45001Dual MTP-12 APC—DSPCatalogued2026-11-11
NVIDIA MMS4A20-XM800NVIDIAOSFPDR45001MPO-12 APC181—Catalogued2026-11-11
NVIDIA MMS4X00-NMNVIDIAOSFP2xDR45001Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NM-FLTNVIDIAOSFP2xDR45001Dual MPO-12 APC172—Catalogued2026-11-11
NVIDIA MMS4X00-NM-HGXNVIDIAOSFP2xDR45001Dual MPO-12 APC151—Catalogued2026-11-11
NVIDIA MMS4X00-NM-TNVIDIAOSFP2xDR45001Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NM16NVIDIAOSFPDR85001MPO-16 APC171—Catalogued2026-11-11
Source Photonics SPQ-8E8-DR-CDFQDSource PhotonicsQSFP-DD2xDR45001Dual MPO-12——Catalogued2026-11-11
Source Photonics SPQ1-8E8-8DO-COASource PhotonicsOSFP2xDR45001Dual MPO-12 APC141—Catalogued2026-11-11

Module specifications and sources

Compare modules
  • Accelink DR8 OSFP LPO

    Silicon photonics linear optics demonstration module with a vendor-published maximum consumption.

  • Accelink RTXM600-201

    Accelink’s OSFP DR8 catalogue module for single-mode Ethernet links. Public text names the ordering code and reach.

  • Accelink RTXM600-400

    Accelink’s QSFP-DD DR8 catalogue module for single-mode Ethernet links. Public text names the ordering code and reach.

  • Arista LPO-800G-2DR4

    Linear pluggable 2x400GBASE-DR4 OSFP that cuts module power below 9 W for 500 m single-mode links.

  • Arista LPO-800G-DR8

    Linear pluggable 800GBASE-DR8 OSFP for 500 m single-mode links at under 9 W.

  • Cisco OSFP-800G-DR8

    DR8 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Cisco OSFP-800G-DR8P

    DR8 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Coherent FTCE4516E1PXM

    DR8 module with an EML transmitter and PIN receiver. Coherent’s parameter table identifies the mechanical package and reach.

  • Eoptolink DR8 OSFP LPO

    Linear optical DR8 family shown in Eoptolink’s OFC demonstration specification. The design omits an in-module DSP/CDR.

  • Eoptolink DR8 QSFP-DD LPO

    Linear optical DR8 family shown in Eoptolink’s OFC demonstration specification. The design omits an in-module DSP/CDR.

  • Eoptolink EOLO-138HG-5H-XDX

    Eoptolink OSFP 8x100G DR module with Dual MPO-12 optics, 500 m over single-mode fiber.

  • Eoptolink EOLO-138HG-5H-xDxLx

    Linear-drive 2x400G DR4 OSFP from Eoptolink’s LPO catalogue: no in-module DSP, for switches with LPO-capable SerDes.

  • Eoptolink EOLO-138HG-5H-XMX

    Eoptolink OSFP 8x100G DR module with MPO-16 optics, 500 m over single-mode fiber.

  • FS LPO-800G-2DR4

    FS-built 2xDR4 OSFP at 8.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS OSFP-2FR4L-800G

    FS-built 2xFR4L OSFP at 15 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS OSFP-DR8-800G

    FS-built 2xDR4 OSFP at 16.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS OSFP800-DR8-B1

    FS-built DR8 OSFP at 16.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS QDD-DR8-800G

    FS-built DR8 QSFP-DD at 16.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS QDD-DR8-800G (dual MPO-12)

    FS-built 2xDR4 QSFP-DD at 16.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • InnoLight 2xDR4 OSFP

    OSFP112 2xDR4 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • InnoLight DR8 OSFP

    OSFP112 DR8 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • Juniper OSFP-2X400G-DR4-P

    Juniper-qualified 800G 2xDR4 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Lumentum 2xDR4 OSFP DSP

    Silicon photonics module with an explicitly documented integrated DSP. Lumentum specifies the connector layout and a typical power upper boundary.

  • NVIDIA MMS4A20-XM800

    Single-port 800G DR4 OSFP (RHS) with 200G-PAM4 lanes, linking ConnectX-8 SuperNICs to Quantum-X800 switches at 500 m.

  • NVIDIA MMS4X00-NM

    2xDR4 switch transceiver with 800G aggregate optical capacity. NVIDIA identifies the finned-top package and maximum power.

  • NVIDIA MMS4X00-NM-FLT

    Flat-top twin-port 2xDR4 single-mode OSFP for DGX H100 systems, 500 m reach.

  • NVIDIA MMS4X00-NM-HGX

    Finned twin-port 2xDR4 OSFP that links Rubin NVL8 systems to Spectrum-4 and Spectrum-5 switches at 500 m.

  • NVIDIA MMS4X00-NM-T

    2xDR4 switch transceiver with 800G aggregate optical capacity. NVIDIA identifies the finned-top package and maximum power.

  • NVIDIA MMS4X00-NM16

    DR8 switch transceiver with 800G aggregate optical capacity. NVIDIA identifies the finned-top package and maximum power.

  • Source Photonics SPQ-8E8-DR-CDFQD

    Source Photonics 800G 2xDR4 QSFP-DD, 500 m reach, built on the company’s in-house EML and VCSEL optics.

  • Source Photonics SPQ1-8E8-8DO-COA

    Source Photonics 800G 2xDR4 OSFP, 500 m reach, built on the company’s in-house EML and VCSEL optics.