800G OSFP transceivers

OSFP is the package of AI fabrics. Compare twin-port 2xDR4, DR8, 2xFR4 and 2xLR4 modules, finned and flat-top, by reach, connector and power.

85 sourced modulesChecked 2026-11-11Rating conditions

Accelink 2xFR4 OSFP LPOAccelinkOSFP2xFR42,0001Dual duplex LC81LPODemonstrated2026-11-11
Accelink DR8 OSFP LPOAccelinkOSFPDR85001Dual MPO-127.51LPODemonstrated2026-11-11
Accelink RTXM600-201AccelinkOSFPDR85001———Catalogued2026-11-11
Accelink RTXM600-210AccelinkOSFP2xFR42,0001———Catalogued2026-11-11
Arista LPO-800G-2DR4AristaOSFP2xDR45001Dual MPO-12 APC92LPOCatalogued2026-11-11
Arista LPO-800G-2FR4AristaOSFP2xFR42,0001Dual duplex LC92LPOCatalogued2026-11-11
Arista LPO-800G-DR8AristaOSFPDR85001MPO-16 APC92LPOCatalogued2026-11-11
Arista OSFP-800G-2FR4AristaOSFP2xFR42,0001Dual duplex LC162—Catalogued2026-11-11
Arista OSFP-800G-2LR4AristaOSFP2xLR410,0001Dual duplex LC162—Catalogued2026-11-11
Arista OSFP-800G-2PLR4AristaOSFP2xPLR410,0001Dual MPO-12 APC162—Catalogued2026-11-11
Arista OSFP-800G-2VSR4AristaOSFP2xVSR4501Dual MPO-12 APC——Catalogued2026-11-11
Arista OSFP-800G-2XDR4AristaOSFP2xXDR42,0001Dual MPO-12 APC162—Catalogued2026-11-11
Arista OSFP-800G-FR4-GAristaOSFPFR42,0001Duplex LC—DSPCatalogued2026-11-11
Arista OSFP-800G-VSR8AristaOSFPVSR8501MPO-16 APC162—Catalogued2026-11-11
Arista OSFP-800G-XDR4-GAristaOSFPXDR42,0001MPO-12 APC—DSPCatalogued2026-11-11
Arista OSFP-800G-XDR8AristaOSFPXDR82,0001MPO-16 APC——Catalogued2026-11-11
Arista OSFP-800G-ZRPAristaOSFP800ZR+———CoherentCatalogued2026-11-11
Cisco DP08SFP8-LRB-A2CiscoOSFP800ZR+1,000,0001Duplex LC—CoherentCatalogued2026-11-11
Cisco DP08SFP8-ZRA-A2CiscoOSFP800ZR120,0001Duplex LC—CoherentCatalogued2026-11-11
Cisco DP08SFP8-ZRB-A2CiscoOSFP800ZR+1,000,0001Duplex LC—CoherentCatalogued2026-11-11
Cisco OSFP-2X400G-FR4CiscoOSFP2xFR42,0001Dual duplex LC UPC14.51—Catalogued2026-11-11
Cisco OSFP-800G-DR8CiscoOSFPDR85001Dual MPO-12 APC171—Catalogued2026-11-11
Cisco OSFP-800G-DR8PCiscoOSFPDR85001MPO-16 APC171—Catalogued2026-11-11
Cisco OSFP-800G-VR8CiscoOSFPVR8501Dual MPO-12 APC161—Catalogued2026-11-11
Cisco OSFP-800G-VR8PCiscoOSFPVR8501MPO-16 APC161—Catalogued2026-11-11
Coherent FTCE3L27E1PCLCoherentOSFP800ZR120,0001Duplex LC—CoherentCatalogued2026-11-11
Coherent FTCE3L27R1PCLCoherentOSFP800ZR+750,0001Duplex LC—CoherentCatalogued2026-11-11
Coherent FTCE3327E1PCLCoherentOSFP800ZR120,0001Duplex LC—CoherentCatalogued2026-11-11
Coherent FTCE3327R1PCLCoherentOSFP800ZR+500,0001Duplex LC—CoherentCatalogued2026-11-11
Coherent FTCE4527E1PxMCoherentOSFPDR8+2,0001MPO-12——Catalogued2026-11-11
Eoptolink 2xFR4 OSFP LPOEoptolinkOSFP2xFR42,0001—81LPODemonstrated2026-11-11
Eoptolink DR8 OSFP LPOEoptolinkOSFPDR85001—81LPODemonstrated2026-11-11
Eoptolink EOLO-138HG-02-XDXEoptolinkOSFP8x100G FR2,0001Dual MPO-12——Catalogued2026-11-11
Eoptolink EOLO-138HG-02-XMXEoptolinkOSFP8x100G FR2,0001MPO-16——Catalogued2026-11-11
Eoptolink EOLO-138HG-5H-XDXEoptolinkOSFP8x100G DR5001Dual MPO-12——Catalogued2026-11-11
Eoptolink EOLO-138HG-5H-xDxLxEoptolinkOSFP2xDR45001Dual MPO-12—LPOCatalogued2026-11-11
Eoptolink EOLO-138HG-5H-XMXEoptolinkOSFP8x100G DR5001MPO-16——Catalogued2026-11-11
Eoptolink EOLO-138HG-10-XDXEoptolinkOSFP8x100G LR10,0001Dual MPO-12——Catalogued2026-11-11
Eoptolink EOLO-138HG-10-XMXEoptolinkOSFP8x100G LR10,0001MPO-16——Catalogued2026-11-11
Eoptolink EOLO-168HG-02-PXEoptolinkOSFPFR82,0001Duplex LC——Catalogued2026-11-11
Eoptolink EOLO-168HG-02-SLxEoptolinkOSFP2xFR42,0001Dual duplex LC—LPOCatalogued2026-11-11
Eoptolink EOLO-168HG-02-XXEoptolinkOSFP2xFR42,0001Dual duplex LC——Catalogued2026-11-11
Eoptolink EOLO-168HG-10-XXEoptolinkOSFP2xLR410,0001Dual duplex LC——Catalogued2026-11-11
Eoptolink EOLO-858HG-01-DXEoptolinkOSFP2xVR4501Dual MPO-12——Catalogued2026-11-11
Eoptolink EOLO-858HG-01-MXEoptolinkOSFPVR8501MPO-16——Catalogued2026-11-11
FS LPO-800G-2DR4FSOSFP2xDR45001Dual MPO-12 APC8.51LPOCatalogued2026-11-11
FS LPO-800G-2FR4FSOSFP2xFR42,0001Dual duplex LC UPC81LPOCatalogued2026-11-11
FS OSFP-2FR4-800GFSOSFP2xFR42,0001Dual duplex LC UPC16.51DSPCatalogued2026-11-11
FS OSFP-2FR4L-800GFSOSFP2xFR4L5001Dual duplex LC UPC151DSPCatalogued2026-11-11
FS OSFP-2LR4L-800GFSOSFP2xLR4L6,0001Dual duplex LC UPC151DSPCatalogued2026-11-11
FS OSFP-DR8-800GFSOSFP2xDR45001Dual MPO-12 APC16.51DSPCatalogued2026-11-11
FS OSFP-DR8L-800GFSOSFP2xDR41001Dual MPO-12 APC171DSPCatalogued2026-11-11
FS OSFP-SR8-800GFSOSFPSR81001MPO-16 APC161DSPCatalogued2026-11-11
FS OSFP-SR8-800G (2VSR4)FSOSFP2xSR4501Dual MPO-12 APC161DSPCatalogued2026-11-11
FS OSFP800-DR8-B1FSOSFPDR85001MPO-16 APC16.51DSPCatalogued2026-11-11
FS OSFP800-XDR8-B2FSOSFP2xXDR42,0001Dual MPO-12 APC16.51DSPCatalogued2026-11-11
InnoLight 2xDR4 OSFP InnoLightOSFP2xDR45001Dual MPO-12 APC——Catalogued2026-11-11
InnoLight 2xFR4 OSFP InnoLightOSFP2xFR42,0001———Catalogued2026-11-11
InnoLight 2xLR4 OSFP InnoLightOSFP2xLR410,0001———Catalogued2026-11-11
InnoLight DR8 OSFP InnoLightOSFPDR85001MPO-16 APC——Catalogued2026-11-11
InnoLight SR8 OSFP InnoLightOSFPSR8501Dual MPO-12——Catalogued2026-11-11
Juniper ORHS-800G-DR8-2-PJuniperOSFPDR8-22,0001Dual MPO-12 APC161—Catalogued2026-11-11
Juniper OSFP-2X400G-DR4-PJuniperOSFP2xDR45001Dual MPO-12 APC161—Catalogued2026-11-11
Juniper OSFP-2X400G-FR4-PJuniperOSFP2xFR42,0001Dual duplex LC UPC161—Catalogued2026-11-11
Juniper OSFP-2X400G-LR4-PJuniperOSFP2xLR410,0001Dual duplex LC UPC161—Catalogued2026-11-11
Juniper OSFP-2X400G-VR4-PJuniperOSFP2xVR4501Dual MPO-12 APC161—Catalogued2026-11-11
Juniper OSFP-8X100G-FR1JuniperOSFP8xFR12,0001MPO-16 APC161—Catalogued2026-11-11
Juniper OSFP-800G-DR8-2-PJuniperOSFPDR8-22,0001Dual MPO-12 APC161—Catalogued2026-11-11
Lumentum 2xDR4 OSFP DSPLumentumOSFP2xDR45001Dual MTP-12 APC—DSPCatalogued2026-11-11
NVIDIA MMA4Z00-NSNVIDIAOSFP2xSR4501Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMA4Z00-NS-FLTNVIDIAOSFP2xSR4501Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMA4Z00-NS-TNVIDIAOSFP2xSR4501Dual MPO-12 APC172—Catalogued2026-11-11
NVIDIA MMS4A20-XM800NVIDIAOSFPDR45001MPO-12 APC181—Catalogued2026-11-11
NVIDIA MMS4X00-NMNVIDIAOSFP2xDR45001Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NM-FLTNVIDIAOSFP2xDR45001Dual MPO-12 APC172—Catalogued2026-11-11
NVIDIA MMS4X00-NM-HGXNVIDIAOSFP2xDR45001Dual MPO-12 APC151—Catalogued2026-11-11
NVIDIA MMS4X00-NM-TNVIDIAOSFP2xDR45001Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NM16NVIDIAOSFPDR85001MPO-16 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NSNVIDIAOSFP2xDR41001Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NS-FLTNVIDIAOSFP2xDR41001Dual MPO-12 APC171—Catalogued2026-11-11
NVIDIA MMS4X00-NS-TNVIDIAOSFP2xDR41001Dual MPO-12 APC172—Catalogued2026-11-11
NVIDIA MMS4X50-NMNVIDIAOSFP2xFR42,0001Dual duplex LC171—Catalogued2026-11-11
NVIDIA MMS4X90-NRNVIDIAOSFP2xLR410,0001Dual duplex LC171—Catalogued2026-11-11
Source Photonics SPQ1-8E8-8DO-COASource PhotonicsOSFP2xDR45001Dual MPO-12 APC141—Catalogued2026-11-11
Source Photonics SPQ1-8E8-8FO-COASource PhotonicsOSFP2xDR42,0001Dual MPO-12 APC141—Catalogued2026-11-11

Module specifications and sources

Compare modules
  • Accelink 2xFR4 OSFP LPO

    Silicon photonics linear optics demonstration module with a vendor-published maximum consumption.

  • Accelink DR8 OSFP LPO

    Silicon photonics linear optics demonstration module with a vendor-published maximum consumption.

  • Accelink RTXM600-201

    Accelink’s OSFP DR8 catalogue module for single-mode Ethernet links. Public text names the ordering code and reach.

  • Accelink RTXM600-210

    Accelink’s OSFP 2xFR4 catalogue module for single-mode Ethernet links. Public text names the ordering code and reach.

  • Arista LPO-800G-2DR4

    Linear pluggable 2x400GBASE-DR4 OSFP that cuts module power below 9 W for 500 m single-mode links.

  • Arista LPO-800G-2FR4

    Linear pluggable 2x400GBASE-FR4 OSFP for 2 km duplex single-mode links at under 9 W.

  • Arista LPO-800G-DR8

    Linear pluggable 800GBASE-DR8 OSFP for 500 m single-mode links at under 9 W.

  • Arista OSFP-800G-2FR4

    Dual-rate 2x400GBASE-FR4 OSFP for 2 km duplex single-mode links; also runs 2x200G-FR4 in 400G ports.

  • Arista OSFP-800G-2LR4

    Dual-rate 2x400GBASE-LR4 OSFP for 10 km duplex single-mode links between switches and sites.

  • Arista OSFP-800G-2PLR4

    2x400GBASE-PLR4 OSFP that breaks out to 8x 100G-LR over parallel single-mode fiber up to 10 km.

  • Arista OSFP-800G-2VSR4

    2x400GBASE-VSR4 OSFP for 50 m multimode links over OM4, interoperable with 400G-VSR4.

  • Arista OSFP-800G-2XDR4

    2x400GBASE-XDR4 OSFP that breaks out to 8x 100G-FR over parallel single-mode fiber up to 2 km.

  • Arista OSFP-800G-FR4-G

    DSP gearbox 800GBASE-FR4 OSFP with 200G-per-lane optics over one duplex LC pair, 2 km.

  • Arista OSFP-800G-VSR8

    800GBASE-VSR8 OSFP for 50 m multimode links over a single MPO-16 APC.

  • Arista OSFP-800G-XDR4-G

    DSP gearbox 800GBASE-DR4 OSFP with 200G-per-lane optics that connects 100G-SerDes switches to 1.6T-generation optics and NICs, 2 km.

  • Arista OSFP-800G-XDR8

    800GBASE-XDR8 OSFP for 2 km parallel single-mode links on a single MPO-16, with 4x200G breakout.

  • Arista OSFP-800G-ZRP

    C-band tunable digital coherent OSFP running 800G-ZR (OIF), 800G-ZR+ and 400G-ZR+ (OpenROADM) for DCI and metro links.

  • Cisco DP08SFP8-LRB-A2

    L-band 800G ZR+ OSFP for routed optical networking: plugs straight into Cisco routers and runs metro to long-haul DWDM without a transponder shelf.

  • Cisco DP08SFP8-ZRA-A2

    C-band 800ZR digital coherent module for data center interconnect over an engineered DWDM link.

  • Cisco DP08SFP8-ZRB-A2

    C-band 800G ZR+ OSFP for routed optical networking: plugs straight into Cisco routers and runs metro to long-haul DWDM without a transponder shelf.

  • Cisco OSFP-2X400G-FR4

    2xFR4 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Cisco OSFP-800G-DR8

    DR8 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Cisco OSFP-800G-DR8P

    DR8 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Cisco OSFP-800G-VR8

    VR8 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Cisco OSFP-800G-VR8P

    VR8 module with an integrated heatsink. Cisco publishes both typical consumption and a maximum with diagnostic monitoring.

  • Coherent FTCE3327E1PCL

    C-band 800ZR digital coherent OSFP for IP-over-DWDM: 800G data center interconnect up to 120 km.

  • Coherent FTCE3327R1PCL

    C-band 800ZR+ digital coherent OSFP for IP-over-DWDM: 800G metro and regional links with 600G and 400G fallback modes.

  • Coherent FTCE3L27E1PCL

    L-band 800ZR digital coherent OSFP for IP-over-DWDM: 800G data center interconnect up to 120 km.

  • Coherent FTCE3L27R1PCL

    L-band 800ZR+ digital coherent OSFP for IP-over-DWDM: 800G metro and regional links with 600G and 400G fallback modes.

  • Coherent FTCE4527E1PxM

    DR8+ module with an EML transmitter and PIN receiver. Coherent’s parameter table identifies the mechanical package and reach.

  • Eoptolink 2xFR4 OSFP LPO

    Linear optical 2xFR4 family shown in Eoptolink’s OFC demonstration specification. The design omits an in-module DSP/CDR.

  • Eoptolink DR8 OSFP LPO

    Linear optical DR8 family shown in Eoptolink’s OFC demonstration specification. The design omits an in-module DSP/CDR.

  • Eoptolink EOLO-138HG-02-XDX

    Eoptolink OSFP 8x100G FR module with Dual MPO-12 optics, 2 km over single-mode fiber.

  • Eoptolink EOLO-138HG-02-XMX

    Eoptolink OSFP 8x100G FR module with MPO-16 optics, 2 km over single-mode fiber.

  • Eoptolink EOLO-138HG-10-XDX

    Eoptolink OSFP 8x100G LR module with Dual MPO-12 optics, 10 km over single-mode fiber.

  • Eoptolink EOLO-138HG-10-XMX

    Eoptolink OSFP 8x100G LR module with MPO-16 optics, 10 km over single-mode fiber.

  • Eoptolink EOLO-138HG-5H-XDX

    Eoptolink OSFP 8x100G DR module with Dual MPO-12 optics, 500 m over single-mode fiber.

  • Eoptolink EOLO-138HG-5H-xDxLx

    Linear-drive 2x400G DR4 OSFP from Eoptolink’s LPO catalogue: no in-module DSP, for switches with LPO-capable SerDes.

  • Eoptolink EOLO-138HG-5H-XMX

    Eoptolink OSFP 8x100G DR module with MPO-16 optics, 500 m over single-mode fiber.

  • Eoptolink EOLO-168HG-02-PX

    Eoptolink OSFP 800G FR8 module with Duplex LC optics, 2 km over single-mode fiber.

  • Eoptolink EOLO-168HG-02-SLx

    Linear-drive 2x400G FR4 OSFP from Eoptolink’s LPO catalogue, for 2 km links without in-module DSP power.

  • Eoptolink EOLO-168HG-02-XX

    Eoptolink OSFP 2x400G FR4 module with Dual duplex LC optics, 2 km over single-mode fiber.

  • Eoptolink EOLO-168HG-10-XX

    Eoptolink OSFP 2x400G LR4 module with Dual duplex LC optics, 10 km over single-mode fiber.

  • Eoptolink EOLO-858HG-01-DX

    Eoptolink OSFP 2x400G VR4 module with Dual MPO-12 optics, 50 m over multimode fiber.

  • Eoptolink EOLO-858HG-01-MX

    Eoptolink OSFP 8x100G VR8 module with MPO-16 optics, 50 m over multimode fiber.

  • FS LPO-800G-2DR4

    FS-built 2xDR4 OSFP at 8.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS LPO-800G-2FR4

    FS-built 2xFR4 OSFP at 8 W maximum and 2 km reach, sold coded for the switch brand you run.

  • FS OSFP-2FR4-800G

    FS-built 2xFR4 OSFP at 16.5 W maximum and 2 km reach, sold coded for the switch brand you run.

  • FS OSFP-2FR4L-800G

    FS-built 2xFR4L OSFP at 15 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS OSFP-2LR4L-800G

    FS-built 2xLR4L OSFP at 15 W maximum and 6 km reach, sold coded for the switch brand you run.

  • FS OSFP-DR8-800G

    FS-built 2xDR4 OSFP at 16.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS OSFP-DR8L-800G

    FS-built 2xDR4 OSFP at 17 W maximum and 100 m reach, sold coded for the switch brand you run.

  • FS OSFP-SR8-800G

    FS-built SR8 OSFP at 16 W maximum and 100 m reach, sold coded for the switch brand you run.

  • FS OSFP-SR8-800G (2VSR4)

    FS-built 2xSR4 OSFP at 16 W maximum and 50 m reach, sold coded for the switch brand you run.

  • FS OSFP800-DR8-B1

    FS-built DR8 OSFP at 16.5 W maximum and 500 m reach, sold coded for the switch brand you run.

  • FS OSFP800-XDR8-B2

    FS-built 2xXDR4 OSFP at 16.5 W maximum and 2 km reach, sold coded for the switch brand you run.

  • InnoLight 2xDR4 OSFP

    OSFP112 2xDR4 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • InnoLight 2xFR4 OSFP

    OSFP112 2xFR4 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • InnoLight 2xLR4 OSFP

    OSFP112 2xLR4 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • InnoLight DR8 OSFP

    OSFP112 DR8 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • InnoLight SR8 OSFP

    OSFP112 SR8 family listed for data center and cloud networks. InnoLight publishes the reach and fiber medium; no ordering code is supplied.

  • Juniper ORHS-800G-DR8-2-P

    Juniper-qualified 800G DR8-2 OSFP-RHS for QFX and PTX 800G ports, rated 16 W maximum.

  • Juniper OSFP-2X400G-DR4-P

    Juniper-qualified 800G 2xDR4 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Juniper OSFP-2X400G-FR4-P

    Juniper-qualified 800G 2xFR4 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Juniper OSFP-2X400G-LR4-P

    Juniper-qualified 800G 2xLR4 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Juniper OSFP-2X400G-VR4-P

    Juniper-qualified 800G 2xVR4 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Juniper OSFP-800G-DR8-2-P

    Juniper-qualified 800G DR8-2 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Juniper OSFP-8X100G-FR1

    Juniper-qualified 800G 8xFR1 OSFP for QFX and PTX 800G ports, rated 16 W maximum.

  • Lumentum 2xDR4 OSFP DSP

    Silicon photonics module with an explicitly documented integrated DSP. Lumentum specifies the connector layout and a typical power upper boundary.

  • NVIDIA MMA4Z00-NS

    Finned twin-port 2xSR4 multimode OSFP for Quantum-2 and Spectrum-4 air-cooled switches, 50 m over OM4.

  • NVIDIA MMA4Z00-NS-FLT

    Flat-top twin-port 2xSR4 multimode OSFP for DGX H100 and liquid-cooled systems, 50 m over OM4.

  • NVIDIA MMA4Z00-NS-T

    Finned twin-port 2x400GbE multimode OSFP for Ethernet switch and NIC links up to 50 m over OM4.

  • NVIDIA MMS4A20-XM800

    Single-port 800G DR4 OSFP (RHS) with 200G-PAM4 lanes, linking ConnectX-8 SuperNICs to Quantum-X800 switches at 500 m.

  • NVIDIA MMS4X00-NM

    2xDR4 switch transceiver with 800G aggregate optical capacity. NVIDIA identifies the finned-top package and maximum power.

  • NVIDIA MMS4X00-NM-FLT

    Flat-top twin-port 2xDR4 single-mode OSFP for DGX H100 systems, 500 m reach.

  • NVIDIA MMS4X00-NM-HGX

    Finned twin-port 2xDR4 OSFP that links Rubin NVL8 systems to Spectrum-4 and Spectrum-5 switches at 500 m.

  • NVIDIA MMS4X00-NM-T

    2xDR4 switch transceiver with 800G aggregate optical capacity. NVIDIA identifies the finned-top package and maximum power.

  • NVIDIA MMS4X00-NM16

    DR8 switch transceiver with 800G aggregate optical capacity. NVIDIA identifies the finned-top package and maximum power.

  • NVIDIA MMS4X00-NS

    Finned twin-port 2xDR4 single-mode OSFP for Quantum-2 and Spectrum-4 air-cooled switches, 100 m reach.

  • NVIDIA MMS4X00-NS-FLT

    Flat-top twin-port 2xDR4 single-mode OSFP for DGX H100 and liquid-cooled systems, 100 m reach.

  • NVIDIA MMS4X00-NS-T

    Finned twin-port 2x400GbE single-mode OSFP for Ethernet switch, ConnectX-7 and BlueField-3 links up to 100 m.

  • NVIDIA MMS4X50-NM

    Finned twin-port 2xFR4 OSFP for 2 km switch-to-switch links on Quantum-2 and Spectrum-4.

  • NVIDIA MMS4X90-NR

    Finned twin-port 2xLR4 OSFP for 10 km single-mode links between switches.

  • Source Photonics SPQ1-8E8-8DO-COA

    Source Photonics 800G 2xDR4 OSFP, 500 m reach, built on the company’s in-house EML and VCSEL optics.

  • Source Photonics SPQ1-8E8-8FO-COA

    Source Photonics 800G 2xDR4 OSFP, 2 km reach, built on the company’s in-house EML and VCSEL optics.